Katanax XFP-01 FluxPenser®
Katanax XFP-01 FluxPenser®
The Katanax XFP-01 FluxPenser® automatic dispenser – Precise and reproducible weighing of flux – includes a scale and is LIMS-compatible.There are two operating modes available for weighing the flux: either weighing a defined quantity (for ICP) or weighing it in a specific ratio to the sample (for XRF). The correct quantity is calculated automatically, and the weighing accuracy is 1 mg.
Product Description
The Katanax XFP-01 FluxPenser® automatic dispenser – precise and reproducible weighing of fusion flux – including scale and LIMS compatibility.
Weighing fusion flux in preparation for borate fusion is usually a process that ties up limited human resources for a repetitive work step. By automating this step, the correct amount of fusion flux is always weighed in with the highest precision, without any intervention by the user. Only the sample itself needs to be weighed manually, the rest is done automatically with the highest precision and reproducibility.
Two operating modes can be selected for weighing the flux. When preparing solutions for subsequent ICP analysis, it is usually preferable to weigh in a defined, fixed quantity of fusion flux. In this case, exactly the same quantity is always dispensed (e.g. 8 grams). The second preferred operating mode for the production of fused beads enables the weighing in of flux in a fixed ratio to the sample (e.g. 1 to 8). The amount of flux to be weighed in is automatically calculated by the FluxPenser® and adjusted to the amount of sample weighed in. This avoids errors when calculating the amount of flux. The desired operating mode is simply selected at the touch of a button on the control unit. For automatic dosing, the fusion flux must be available as granulate or in the form of beads (pre-fused beads); the FluxPenser® is not suitable for weighing in powdered flux. In general, weighing is carried out with an accuracy of 1 mg; it is not necessary for the user to provide a suitable scale. There is also no need to decant the flux with the risk of contamination or to refill a storage container, as the original container of the fusion flux also serves as a storage container. This also efficiently prevents the unintentional use of an unsuitable fusion flux mixture. Once the weighing process is complete, the data can be transferred directly to the software of the XRF device or directly to the LIMS (Laboratory Information System) for documentation and further processing.
With the XFP-01 FluxPenser® from Katanax, the fusion flux is weighed out with maximum precision and reproducibility while reducing errors at the same time.
Downloads
Videos
No videos available at the moment.
Specifications
Controls: membrane keypad
Mains connection: 230 V / 50 Hz
Max. power consumption: 6 W
Dimensions (including scales): 50 cm (H) x 50 cm (W) x 50 cm (D)
Options and Accessories
Applications
• Preparation of fused beads from a lithium borate fusion for XRF analysis
• Preparation of solutions (acid digestion) for ICP-OES / ICP-MS analysis
• Preparation of peroxide fusions