Gamry – Dr Bob’s Measurement Cell Set
Gamry – Dr Bob’s Measurement Cell Set
Dr Bob’s sensor cell set, made entirely from inert materials, is used in a wide range of applications to characterise unknown electroactive species.The Dr. Bob’s measuring cell set can be used as an electrochemical measuring cell with micro- and macro-working electrodes made of platinum, gold and glassy carbon for a wide range of applications, such as studies on enzymes and catalysts, electrochemical sensors, galvanic cells, and the redox potentials of inorganic complexes, etc. Alternative electrode materials must be available in working electrode holders with a length of 110 mm and outer diameters between 6.5 mm and 7.5 mm.
Product Description
The macro (Ø = 3 mm) or micro working electrode (Ø = 10 µm / 11 µm) used in the Dr Bob’s measuring cell set can come into contact with a minimum of 1 ml or a maximum of 30 ml electrolyte volume.
The Pyrex® conical flask of the Dr Bob’s measuring cell set has a total of five connections. Three glass sleeves with an internal thread from ACE GLASS INC. Vineland / NJ ( #7 Ace – Thread) and two 14/20 ground glass sleeves. The vertical #7 Ace thread in the centre is used to attach the working electrode via a nylon or PTFE threaded bush, sealed by an O-ring made of FETFE.
A further #7 ace thread extending from the side is used in the same way to accommodate a Luggin capillary or a salt bridge for use with a Gamry reference electrode, which is held in the Luggin capillary via the single #11 ace thread with the corresponding threaded bush. The third #7 ace thread attaches a glass sleeve with a fused glass frit at the lower end and a platinum wire (150 mm Pt-wire; Ø = 0.4 mm) housed in it as a counter electrode.
A 14/20 core / #7 ace thread adapter with lateral hose olive (gas flow adapter) is used via the 14/20 ground joint sleeve to accommodate an inert gas supply for purging via a nozzle tube (bubbler), as an inert gas supply, for sampling gases or for venting. The second connection via the 14/20 ground joint sleeve is used as an addition for temperature measurements, the addition of reagents or also for venting. The connection can also be sealed with polyethylene plugs. The standard set includes a stand, which saves you having to work with the awkward combination of stand and stand ring. With the set including heating/cooling jacket, the Dr Bob’s measuring cell can be operated free-standing.
Downloads
Videos
The Gamry Interface 1010 Potentiostat Starter PackSpecifications
DIMENSIONS10 cm (W) x 10 cm (L) x 30 cm (H)
SYSTEM
Material: Pyrex®, PTFE, Vycor glass, ACE FETFE, platinum, polyethylene
Type: Multi-necked flask with 2x 14/20 standard ground joints and 3x #7 Ace thread
Volume: 1 ml – 30 ml
CONFIGURATION
Working electrode connection (
type) #7 Ace – Thread
Working electrode connection (Ø / mm) 6.5 – 7.5
Working electrode connection (L / cm) 5 (min.) - 11 (< 5 ml)
Luggin capillary connection (type) #7 Ace – Thread
Luggin capillary / electrolyte contact Vycor® disc Ø, 3.5 mm
Reference electrode connection (type) #11 Ace – Thread
Reference electrode connection (Ø / mm) 9 – 11.5
Counter-electrode connection (type) #7 Ace – Thread / Glass sleeve (frit)
Counter-electrode 150 mm Pt wire / Ø 0.4 mm
Inert gas purge connection (type) 14/20 sleeve
Inert gas purge 14/20 core / #7 Ace – adapter with side hose connector (purge / feed / vent)
Additional connection (type) 14/20 sleeve / 5x PE plugs
Options and Accessories
Measuring cells and accessories:
• Interface 1000 Potentiostat/Galvanostat/ZRA
• Interface 1010 Potentiostat/Galvanostat/ZRA
• Reference 600 Potentiostat/Galvanostat/ZRA
• Reference 600+ Potentiostat/Galvanostat/ZRA
• Reference 3000 (AE) Potentiostat/Galvanostat/ZRA
• Dr. Bob’s Cell with Jacketed Cell (excludes working and reference electrodes)
• DBC Glass Cell, Standard
• DBC Glass Cell, Jacketed
• Cell stand for standard DBC glass cell
• Counter electrode bridge tube
• Platinum counter electrode, 15 cm
• Bubbler adapter, 14/20 to #7 Ace thread
• Bubbler
• Bubbler Hose Connector for #7 Ace Thread
• Reference electrode bridge tube
• #7 Ace-thread bushing with O-ring
• #11 Ace-thread bushing with O-ring
• Stir bar, 2×6 mm
• PE stopper for NS14/20 joint
• Vycor frit with Teflon heat-shrink tubing, 3.5 mm (5 pcs)
• Platinum working electrode – 3 mm disc, 7 mm OD
• Gold working electrode – 3 mm disc, 7 mm OD
• Glassy carbon working electrode – 3 mm disc, 7 mm OD
• Platinum microelectrode – 10 µm, 7 mm OD
• Gold microelectrode – 10 µm, 7 mm OD
• Glassy carbon microelectrode – 11 µm, 7 mm OD
• Electrode Polishing Kit
• Plate glass, 10 x 10 cm
• Polishing Cloth, 102 mm diameter, PSA backing, pack of 20
• Alumina suspension, 0.05 µm, 180 ml
• Calomel (SCE) reference electrode
• Silver/silver chloride reference electrode
• Mercury sulphate reference electrode (without chloride anions)
• Mercury oxide reference electrode for alkaline media
• Silver/silver nitrate reference electrode for non-aqueous electrolytes
• SCE refill solution (120 ml)
• Ag/AgCl refill medium (120 ml)
• Vycor frit with Teflon heat-shrink tubing, 3.5 mm (5 pieces)
• KT glass frit with Teflon heat-shrink tubing, 3.5 mm (5 pieces)
• Polymer exchange frits for mercury oxide reference electrode
Applications
• Measuring Surface Related Currents using Digital Staircase Voltammetry
• Characterisation of a Supercapacitor using an Electrochemical Quartz Crystal Microbalance
• Compliance Voltage: How Much is Enough
• Two, Three and Four Electrode Experiments
• Understanding iR Compensation
• Testing Electrochemical Capacitors Part 2: Cyclic Charge Discharge and Stacks
• Testing Electrochemical Capacitors Part 1: CV, EIS, and Leakage Current
• Testing Lithium Ion Batteries
• Use of Transmission Lines for Electrochemical Impedance Spectroscopy
• Testing Electrochemical Capacitors: Part 3 – Electrochemical Impedance Spectroscopy
• Verification of Low-impedance EIS Using a 1mΩ Resistor
• EIS Measurement of a Very Low Impedance Lithium Ion Battery
• Demystifying Transmission Lines: What are they? Why are they useful?