Gamry – Euro Corrosion Cell Set
Gamry – Euro Corrosion Cell Set
The Euro Corrosion Cell Set is the entry-level model for electrochemical corrosion measurements on cylindrical test specimensThe Euro Corrosion Test Cell is designed for electrochemical corrosion measurements in electrolyte volumes ranging from 125 ml to 175 ml. The components of the Euro Corrosion Test Cell kit have been selected for their high chemical resistance; however, they are not suitable for use in hydrofluoric acid (HF) or in alkaline electrolytes.
Product Description
The cylindrical working electrode used (820-00005 = C1018 P/N 410 Series; L 12.7 mm; Ø 9.5 mm; 3-48 internal thread) from Alabama Specialty Products can come into contact with a minimum 125 ml or maximum 175 ml electrolyte volume in the Euro Corrosion measuring cell set. Made of Pyrex®, the EuroCell has a total of five favourable connections. Two glass sleeves with an internal thread from ACE GLASS INC. Vineland / NJ ( #7 Ace Thred), two 14/20 ground glass sleeves and one 24/40 ground glass sleeve.
The vertical 24/40 sleeve in the centre accommodates an adapter (935-00005 = Adapter, 24/40 to Ø 8 mm tube) for a glass tube (930-00039 = Tube, Glass, Electr. Holder, EuroCell), into the centre of which the working electrode can be screwed with a threaded rod (820-00036 = Threaded rod). To ensure that only the working electrode and not the metal threaded rod comes into contact with the electrolyte, two Teflon sealing elements (820-00004 = Sample Rod Centering Washer; 820-00001 = Teflon Compression Gasket) are provided above and below the glass tube, which are locked against the working electrode with a nut (850-00005 = Hex 8-32 x 12.7 mm).
A #7 Ace thread extending from the side is used to accommodate a Luggin capillary (930-00045 = Reference Electrode Bridge Tube) for use with a Gamry reference electrode, which is held in the Luggin capillary via the single #11 Ace thread with the corresponding threaded bush. The second #7 Ace thread attaches a graphite rod for use as a counter electrode.
A 14/20 core / #7 ace thread adapter with lateral hose olive (930-00033 = gas flow adapter) is used to accommodate an inert gas supply, for flushing via a nozzle tube with frit (930-00040 = bubbler), as a shielding gas supply or for venting. The second connection via the 14/20 ground joint sleeve is used as an addition for temperature measurements, the addition of reagents or also for venting. The connection can also be sealed with polyethylene plugs.
Downloads
Videos
The Gamry Interface 1010 Potentiostat Starter PackSpecifications
DIMENSIONSØ6 mm x 22 mm (H) – Standard version
Ø11.5 mm x 23 mm (H) – Version with heating/cooling jacket
SYSTEM
Material: Pyrex®, PTFE, Vycor glass, ACE PTFE, graphite, polyethylene
Type: Multi-neck flask with 2x 14/20 standard ground joints and 2x #7 Ace thread
Volume: 125 ml – 175 ml
CONFIGURATION
Working electrode connection (type) 24/40 ground sleeve
Working electrode connection (Ø / mm) 7 – 9
Working electrode connection (L / cm) 5
Working electrode area (cm²) 5
Luggin capillary connection (type) #7 Ace – Thread
Luggin capillary / electrolyte contact Vycor® disc Ø, 3.5 mm
Reference electrode connection (type) #11 Ace – Thread
Reference electrode connection (Ø / mm) 9 – 11.5
Counter electrode connection (Type) #7 Ace – Thread
Counter electrode 150 mm graphite rod / Ø 6.3 mm
Inert gas purge connection (type) 14/20 sleeve
Inert gas purge 14/20 core / #7 Ace – adapter with side hose connector (purge / feed / vent)
Additional connection (type) 14/20 sleeve / 5x PE plugs
Options and Accessories
Measuring cells and accessories:
• Interface 1000 Potentiostat/Galvanostat/ZRA
• Interface 1010 Potentiostat/Galvanostat/ZRA
• Reference 600 Potentiostat/Galvanostat/ZRA
• Reference 600+ Potentiostat/Galvanostat/ZRA
• Reference 3000 (AE) Potentiostat/Galvanostat/ZRA
• Jacketed Euro Corrosion Cell Kit (excludes reference electrode)
• Euro Corrosion Cell Stand Kit (for non-jacketed cell)
• Standard Euro Corrosion Cell
• Jacketed Euro Corrosion Cell
• C1018 Mild Steel Sample
• Sample Rod for Euro Cylindrical Specimen Holder, Stainless Steel
• Hex Nut for Sampling Rod, Stainless Steel
• Teflon gasket for sample rod
• Centring Washer for Sample Rod
• Glass electrode holder
• 24/40 Teflon adapter for glass electrode holder
• Graphite rod, counter electrode, 6 inches
• Reference Electrode Bridge Tube with Vycor Frit
• Bubbler, fritted
• 14/20 adapter for bubbler
• #7 Ace-thread bushing with O-ring
• #11 Ace-thread bushing with O-ring
• Counter-electrode bridge tube kit
• Bubbler hose connector for #7 Ace-thread
• PE stopper for NS14/20 joint
• Calomel (SCE) reference electrode
• Silver/silver chloride reference electrode
• Mercury sulphate reference electrode (without chloride anions)
• Mercury oxide reference electrode for alkaline media
• Silver/silver nitrate reference electrode for non-aqueous electrolytes
• CE refill solution (120 ml)
• Ag/AgCl refill medium (120 ml)
• Vycor frit with Teflon heat-shrink tubing, 3.5 mm (5 pieces)
• KT glass frit with Teflon heat-shrink tubing, 3.5 mm (5 pieces)
• Polymer exchange frits for mercury oxide reference electrode
Applications
• Two, Three and Four Electrode Experiments
• Understanding iR Compensation
• THE Method for Crevice Corrosion Repassivation Potentials
• Polarisation Resistance Tutorial – Getting Started
• Comparison of Corrosion Rate Calculated by EFM, LPR, and EIS
• Getting Started with Electrochemical Corrosion Measurement